ASTM C 31M PDF

This practice covers procedures for making and curing cylinder and beam specimens from representative samples of fresh concrete for a construction project. C 31/C 31M Practice for Making and Curing Concrete Test 1 This test method is under the jurisdiction of ASTM Committee C09 on. Concrete. ASTM Standards: 2. C 31/C 31M Practice for Making and Curing Concrete Test. Specimens in the Field. C 42/C 42M Test Method for Obtaining and Testing .

Author: Shaktigore Shakora
Country: Japan
Language: English (Spanish)
Genre: Literature
Published (Last): 20 January 2017
Pages: 368
PDF File Size: 15.95 Mb
ePub File Size: 20.65 Mb
ISBN: 348-8-87309-265-5
Downloads: 69066
Price: Free* [*Free Regsitration Required]
Uploader: Bami

This practice is not satisfactory for making specimens from concrete not having measurable slump or requiring other sizes or shapes of specimens.

Unless you are signed in to a HubPages account, all personally identifiable information is anonymized. Combining values from the two systems may result in non-conformance with asmt standard.

ASTM C31 – Making & Curing Concrete Specimens in the Field

We partner with Say Media to deliver ad campaigns on our sites. The ASTM procedure says that Prevent asfm drying of the surfaces of the beams between the removal of the water storage tank and testing. Bucket of Water and Rag — Please clean off your equipment after each use to help keep it in spec. Historical Version s – view previous versions of standard Work Item s – proposed revisions of this standard Translated Version s: We 3m1 use remarketing pixels from advertising networks such as Google AdWords, Bing Ads, and Facebook in order to advertise the HubPages Service to people that have visited our sites.

ASTM C31 – Making and Curing Concrete Test Specimens in the Field | Owlcation

This website uses cookies As a user in the EEA, your approval is needed on a few things. You will get a representative sample of freshly mixed concrete from the truck or mixer, perform slump, temperature, and air content tests on it, and then make cylinders that will be taken back to the lab.

We recommend users of early versions of Internet Explorer to update to Version 10 or later. If you are making multiple sets of cylinders with more than one truck, write the number on the batch ticket and on your paperwork so you know which truck goes with which set of cylinders. The bottom layer must be penetrated to the bottom of the mold, and for the layers above it you must go through that layer and about an inch into the layer below it.

  BUKU IQRO 1-6 PDF

The cylinder diameter needs to be at least 3 times as wide as the largest piece of aggregate the nominal aggregate sizeso we only make 4x8s when the nominal aggregate size is less than 1.

It is very important for the integrity of any test to have clean, working equipment. Disposable molds are to be calibrated every time a new lot arrives. This is used to provide data on traffic to our website, all personally identifyable data is anonymized. No data is shared with Paypal unless you engage with this feature. It helps to group your equipment by test, so you have everything you need for each test in one place. Some articles have YouTube videos embedded in them.

Protect the surfaces of both in the same manner the structure is protected, as best as possible. After you rod each layer you need to tap the outside of your mold with an open hand about 10 to 15 times plastic molds may be damaged if you use a mallet to let excess air out of the cylinder and close the holes from rodding ASTM C31 Paragraph 9.

ComScore is a media measurement and analytics company providing marketing data and analytics to enterprises, media and advertising agencies, and publishers. For a volume license the PDF is licensed to the person in which it is assigned.

If you are also doing slump, temperature, and air content on this sample, note that you must have these cylinders made within 15 minutes of receiving the sample, so plan accordingly and set up your work area beforehand ASTM C Paragraph 4.

Ours has shelves labeled with a date, and we store them on the day they are meant to be broken, not the day they were made. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

You can use asgm to streamline signing up for, or signing in to your Hubpages account. To strip a cylinder, insert the stripping tool into the top of the mold in the gap between the concrete and the mold, and hammer it all the way to the bottom of the mold.

  ANICHINI CONTI ANALISI MATEMATICA 2 PDF

Use a back-and forth left-to-right sawing motion, starting in the middle and working away from you, then come back to the middle and move the strike-off bar towards you, still performing the same sawing motion.

This is used to display charts and graphs on articles and the author center. Rodding is only used if the slump is greater asm equal to one inch; if the mix is very dry and the slump comes out to less than an inch you will have to vibrate the concrete to consolidate it thoroughly.

ASTM C31 – Making and Curing Concrete Test Specimens in the Field

If representing pavements of a slab on grade, bank the sides and ends with earth or sand that must be kept damp, leaving the top surface exposed. Be sure to write on your paperwork which location you are making or leaving your cylinders at, because someone else may be the one to come pick them up.

They must not leak when water is poured into them empty. Cylinders and beams can be placed in moist rooms or water storage tanks, but beams must be moved into water saturated with calcium hydroxide at the same temperature at least 20 hours prior to testing.

Some articles have F Maps ast in them. When strength is used as a basis for acceptance of concrete, specimens must be molded and cured according to ASTM C Strike-off Bar — Must be clean and level and must have a flat and even plane surface.

Transportation and Curing Procedures Cylinders need to be picked up anywhere from 18 to 48 hours after they are made. Significance and Use of ASTM C31 Concrete cylinder samples are made for your lab technician to break in a hydraulic press machine and find the compressive strength of the concrete that is being poured for a specific part of a structure. After you have consolidated the concrete, you will need to strike off the concrete to provide a smooth surface.

This supports the Maven widget and search functionality. This practice is not satisfactory for making specimens from concrete not having measurable slump or requiring atsm sizes or shapes of specimens.

Author: admin